Whats app/ Zalo/ Wechat/ Telephone:0086-18575511218

E-mail: sales@roc-ele.com / info@roc-ele.com

Product Center

Contact Us

 ROC Precision Intelligent Technology Co., Ltd.

Water-based cleaner

Your current location: HOME > Water-based cleaner >

Rosin Water-based cleaner T1002G Msds

  • Category:Water-based cleaner

  • The number of clicks:
  • Release date:2020-05-21
  • 在线询价
  • Detailed introduction

Part I Chemical products and company identification

chemical product
Product Name: TENICK T1002G
Recommended use: For the removal of furnace agglomerated flux, fixture high temperature welding residual flux.
Company logo
Brand
Supplier (Company Name / Address / Phone)
Company website
TENICK
Singapore
Supplier name:SINGAPORE TENICK CLEANING TECHNOLOGY PTE.LTD.
supplier address:50 Raffles Place,#34-04 Singapore Land Tower Singapore 048623
Supplier phone:(65)65326932 
www.tenic.sg

Part II Hazard Overview

Classification: This product is not dangerous.
Hazard label
Health hazards: Excessive contact can cause eye, skin or respiratory irritation.
Environmental hazards: No obvious hazards.
Explosion hazard: Non-flammable liquid, no explosion hazard.
Part III Composition and composition information
Composition: Mixture.
Ingredient information:
name CAS number  content
Togashi compounds  ——  0.1-15%
Carbon silicon compound  ——  15-35%
Nitrogen containing carboxylic acid compound  ——  15~40%
1-ethoxy-2-propanol  1569-02-4    5~10%
2-isopropoxyethanol  109-59-1  5~10%

Part IV First Aid Measures

Inhalation
Use appropriate respiratory protection, if breathing irritation, dizziness, nausea, or confusion, seek medical attention immediately. Such as
If breathing stops, use mechanical equipment to help with ventilation, or perform mouth-to-mouth resuscitation first aid.
skin contact
Wash the area with soap and water. Take off contaminated clothing. Contaminated clothing should be washed before wearing.
eye contact
Rinse thoroughly with water. Seek medical assistance if irritation occurs.
Ingestion:
Get medical attention immediately. Do not induce vomiting, maintain rest, and timely medical care
Part V Fire Fighting Measures
Extinguishing media
Suitable extinguishing media: Use fire water spray, foam, dry chemical (dry powder) or carbon dioxide (CO2) to extinguish the fire.
water
Improper extinguishing media: None.
Fire
Fire instructions: Evacuate the area. Prevent the control of fire or diluted effluent from flowing into rivers, sewers or drinking water sources.
Firefighters should use standard protective equipment, use self-contained breathing apparatus in confined spaces, and expose to fire by spraying water.
The surface of the disaster cools down and protects the staff.
Fire hazard: Firefighters should consider using the protective equipment described in Section 8.
Hazardous combustion products: incomplete combustion products, carbon dioxide
Dangerous characteristics
No obvious hazard characteristics
Part VI Emergency measures for accidental leakage
Leakage treatment
Ground leaks: Do not touch or walk through leaked products. Avoid running into waterways, sewers, basements or narrow areas. .
Transfer to dry soil, sand or other non-inert materials and transfer to a container.
Water leakage: Precipitation and/or proper use of contaminants in open waters, if permitted by local agencies and environmental agencies
Powder. Consult the relevant experts for specific requirements for the disposal of all recycled materials and ensure compliance with local waste disposal regulations.
Part VII Operational Processing and Storage
Operational attention
Avoid prolonged or frequent contact with the skin. After treatment, wash your hands immediately before taking a break.
Loading and unloading temperature: room temperature
Transportation temperature: room temperature
Storage attention
Keep the container tight. Handle the container carefully. Store in a cool, well-ventilated place. Do not pressurize, cut, or
Heat or weld. Empty containers may contain product residues and should not be used until they have been professionally cleaned or reformed.
Storage temperature: normal temperature
Storage pressure: room temperature
Compatible materials and coatings: polyethylene; polypropylene; polyester, etc.
Incompatible materials and coatings: iron, aluminum, etc.
Part VIII Contact Control / Personal Protection
engineering control
Strictly closed, providing sufficient local exhaust. There are emergency showers such as eyewash.
personal protection
Respiratory protection: When the concentration in the air exceeds the standard, a filter-type gas mask (half mask) should be worn.
Hand protection: Use chemical resistant gloves (nitrile gloves).
Eye protection: If it is possible to contact, it is recommended to use safety glasses with side shields.
Skin and body protection: Use chemical/oil resistant antistatic overalls.
Other protections: Maintain good personal hygiene, such as washing hands after handling the product, and eating, drinking and/or Wash your hands before smoking. Clean your work clothes and protective equipment regularly to remove contaminants. Discard contaminated clothing that cannot be washed And shoes.
Part IX Physical and chemical properties
Physical state: liquid
Appearance: colorless to pale yellow
Smell: characteristic smell
Smell threshold: no data
Relative density (@ 20°C): 1.0358
Flash point : none
pH: 9~10
Melting point: <0°C
Boiling point : >100°C
Auto-ignition temperature: none
Decomposition temperature: no data
Relative vapor density (air = 1): not applicable
Saturated vapor pressure: no data available
Logogram of n-octanol/water partition coefficient: No data available
Solubility: soluble in water
Other physical properties: None
Part 10 Stability and reactivity
Stability: The product is stable under normal conditions.
Avoid contact conditions: Avoid excessive heat. High energy ignition source.
Avoid contact with substances: Strong oxidants, acids.
Hazardous decomposition products: In general, no decomposition occurs.
Hazardous Polymerization: No dangerous polymerization will occur.
Part XI Toxicological Information
Toxicological information
Acute toxicity LD 50 (rat) / oral LC50 rat) / oral LD 50 (rabbit) / percutaneous other
> 2000 mg/kg >1000 mg/m3 > 2000 mg/kg no
Subacute and chronic toxicity no data
Irritating no data
other no data

Section 12 Ecological Information

Ecotoxicity This product is considered harmless to aquatic organisms
Biodegradability Rapid biodegradation
Non-biodegradable  Non-biodegradation is not obvious
Bioaccumulation no data
Other harmful effects no data

Section 13 Discarding Instructions

Disposal advice

This product is not suitable for disposal by deep burial and is not suitable for discharge into public sewers, drainage systems or natural rivers.

Empty drums should be recycled, recycled or disposed of by qualified or licensed agencies. In all cases, care must be taken to ensure compliance with national and local laws.

Disposal considerations

Refer to relevant government regulations.

Part Fourteen Transport Information
Package identification Packing category
wrapping method Refer to national and local regulations before disposal. 
Transportation considerations Lightly load and unload during handling to prevent damage to packaging and containers. 
Ground transportation Land transport is not regulated 
Sea Shipping is not regulated
air transport Air transport is not regulated 

Part 15 Regulatory Information

Corresponding provisions have been made for the safe use, production, storage, transportation, loading and unloading of chemical dangerous goods.

Regulations for the Safety Management of Chemical Dangerous Goods, implemented on December 1, 2011

General rules for the classification and hazard of chemicals GB 13690-2009 Implementation on May 1, 2010

SAFETY DATA SHEET Content and project sequence GB

16483-2008 Implemented on February 1, 2009

Regulations for the preparation of chemical safety labels GB 15258-2009 Implementation on May 1, 2010

Water Pollution Prevention Law / Waste Pollution Prevention and Control Act

Section 16 Additional Information
Note: This material applies only to the substance specified and may not apply to the mixing of the substance with other substances or during use.
This information is known to the product and is believed to be accurate and reliable. However, the accuracy, reliability and reliability of the information of the company
No commitment or guarantee of completeness. The user must be responsible for the suitability and completeness of the material for his or her own application.